Fill out my online form.
40K 9in1 Lipo Laser Ultrasonic Cavitation Machine Vacuum Radio Frequency For beauty Salon Home use Body Shape Slimming Equipment Contraindication 1. Pregnant women or women during menses. 2. Epileptic 3. Patients with malignancy. 4. Patient whose wound after operation has not healed up. 5. Acute inflammation or epidemical patients. 6. Those with heart diseases or with heart pacemaker. 7. Those with kidney (gall-stone) disease. 8. Those with embedded metal object or silica gel. 9. Those in menses, under birth control, with emiction incontinence period, or undergone belly operation. 10. Those with genetic hypersensitivity. NOTICE 1. Be sure to use the special ultrasonic gel. 2. Handle the heads with care, avoid knocks. 3. Use and prepare enough gel to avoid overheating the heads. 4. Don't linger too long on a single region and avoid the bones. 5. Don't use disinfectants to disinfect the heads, use wet cotton or dry towel instead. 6. Make sure the power supply is connected and plugged well. 7. If the machine is not for use for a long period of time, switch it off and unplug the power supply. 8. Operators and patients should not wear any metallic jewellery or items. 9. The machine should be rested every hour of continuous operation for about 10 minutes. 10. During the operation,be sure not to accept other treatments.
Package Including: Eye RF handle *1 Face RF handle *1 Body RF handle *1 CAVI handle *1 VAC RF handle *1 Cold handle *1 BIO& photon handle *1 EMS handle *1 Laser Lipolysis *8 Power cord *1 Belt *2 Bracket *3 Users Guide 1. Operation schematic drawing of 40K cavitation explode work head Massage the fat of thigh in circles 2. Operation schematic drawing of sextupole RF laser head for body Waist and abdomen care (25 minutes, 2-3 days/time)
② . Massage chest nest, both sides of former abdomen and below the navel (in diamond formation) from inside to outside in circles ① . Massage to navel as center and gradually expanding the range . ③ . Concentrated on the fat from 4 directions the navel as center ④ . Massage from inner rib to outer edge in circles. ⑤ .Massage from end of pelvis to groin in circles. ⑥ . Massage back and forth from inner rib to outer edge in straight line. ⑦ . Lift the Hip and the lower part of the body care (30minutes, 2-3 days/time) ⑧ . Concentrated from hip to groin in circles or straight line. Repeat massaging from inner to outer edge. Recycle the motion. 3. Operation schematic drawing of FACE RF work head for face. 1. Massage the mandible center in circles to produce deep heat. 2. Massage lower jaw in lines. 3. Massage the triangle zone of both sides of the face in circles. 4. Massage from jaw to angulus oris to ear in lines. BIO Microcurrent & LED photon Treatment Application : forehead. eyes' around, cheek, mouth, double chin, neck, body Microcurrent-safe and painless facial helps erase fine lines and wrinkles, while firming your skin and defining your features Method : Use the probe to massage the specific part of skin to be treated circularly after applying the essence adjust the output energy and mode There are 4 modes, M1, M2, M3, and M4, which are described as follows: "M1" works continuously, "M2" works continuously for 2 seconds, and pauses for 2 seconds. "M3" works continuously for 1 second and pauses for 1 second. "M4" works continuously for 0.5 seconds and pauses for 0.5 seconds. The handle can adjust 7 photon modes. First, turn on the switch on the machine screen to ensure that the power is greater than 0,Press "-" "+" to adjust the LED color. 1. Red: Vitalize be suitable for any skin, promote blood circulation, and regenarate collagen protein in order to smooth skin and heal xerodermia, exuviation, degenerate losing hair and folliculosis. 2. Green:Balance Normalize sebaceous glands, Reduce black heads and sores, balance moisture. 3. Blue: Calm be suitable for sensitive, oil, and comedo skin-diminish and eliminate acne bacilus to remove acne, whelk, promote to compound protein with ossein, activate skin, tighten slack skin and gravidity winkle. 4. Purple: Drain Renew skin, reduce wrinkles. 5. Orange: Brighten whiten decompose pigment, and smooth scares. 6. Cyan: Defense strengthen the ability to protect skin, calm down, release stress. 7. White: Guide guide skin to absorb nutrients and anti-aging. 8. Loop 40Khz Ultrasonic handle (Cavitation) Strong sound wave explosion fat head - with collective strong sound wave head, strong sound wave of 40KHZ may be emitted to human body for impacting fat cells fiercely and causing friction motion between fat cells. This may cause effective consumption of calories and moisture in fat cells and reduce the size of fat cell. What's more, sound wave vibration may cause fierce impact of fat cells to make them be exploded instantaneously, reduce the amount of fat cells and thereby achieve the effects of removing fat. There is 4 mode of M1, M2, M3 and M4 as described as follows: "M1" is continuous working for 3 sec and discontinuous for 3 sec. "M2" is continuous working for 2 sec and discontinuous for 2 sec. "M3" is continuous working for 1 sec and discontinuous for I sec. "M4" is continuous working for 0.5 sec and discontinuous for 0.5 sec. Operate with the 40KHz cavitation head for 15-20 minutes with mainly the spiral movement on body Press "-" "+" to adjust the duration of operation. Touch to ajust the cavitation mode among M1,M2,M3,M4 modes. Clicking "-" to decrease the strength or click "+" to increase it. Press "START" to start the strong sound wave explosion fat head. Method : Use the probe to massage the specific part of skin to be treated circularly after applying the slimming cream for about 15 to 20 minutes. It could quicken the blood circulation in the treated part of skin and has the effect of decomposing fat. Matters needing attention: 1. Apply slimming cream or cooling gel to the part of skin to be treated before the treatment. 2. Keep close contact between the probe and the skin. 3. Adjust the intensity from low level to high level. 4.Do not keep the applicator at the same place 5.Move the applicator slowly, But constantly 6.Avoid the treatment over bone and do not aim directly to the joint 7.Pay attention to the temperature of the cavitation handle when using it, and stop using it for ten minutes after half an hour of use. 8. Cavitation is forbidden to work without gel. If it doesn't work and you need to re-adjust the frequency, please contact the supplier. Vacuum Bipolar RF handle Dissolve fat, enhance lymphatic drainage, firm skin and improve skin elasticity. It has an anti-geocentric attraction effect on the skin. That is attracting and outspreading the fibrillar connective tissue of different cortexes through the rhythmic massage and effectively break down subcutaneous fat and reduce cellular tissue accumulation of fat. Coupled with the use of the patents methodology of massaging deeply with roller over different parts of the body to bring up fat layer in dermis curium and subcutaneous. It releases micro-vascular lymphatic vessels at the same time promoting metabolism and converts fat cells in a passive movement to fatty acids. Toxins within the cells are also eliminated from lymphatic system. In vitro the detoxification enhances the function as many as four times. The skin will become more elastic and luster. The perfect "healthy body sculpture management" expert.
Press "VAC RF" in the display screen to select vacuum bipolar RF output, Set the RF mode : Touch to ajust the RF mode among Auto,M1,M2,M3 modes. Automatic mode always output, M1 output for 0.5 seconds, M2 output for 1 second, M3 output for 1.5 seconds,select the suitable intensity (adjust according to the customer's acceptable level, 20%-60%is recommended) and press "START" key to begin operation. Adjust the appropriate vacuum suction ( Adjust the knob on the back ) Method: After applying oil on the skin area to be treated, perform circulatory massage on specific areas of the skin for about 30 to 40 minutes, which can speed up blood circulation, It has the function of decomposing fat. Note: 1.Apply sufficient amount of Oil 2.Keep close contact between the probe and the skin. 3. Adjust the intensity from low level to high level. 4.Do not keep the applicator at the same place 5. Move the applicator slowly, but constantly. 6. Avoid the treatment over bone and do not aim directly to the joint 7.Always make a skin fold in order to get better access to the fat tissue 8. In case of resting during treatment, please "PAUSE" and then "STOP" to avoid over-output of the machine 9. Wipe off the oil inside with alcohol/paper towel after use, then put it on the shelf.